Supermicro Server 1029U-TN10RT 1U Intel Xeon Scalable Processor(LGA 3647) DDR4 10x2.5" Hot-Swap NVMe/SAS3 2x10GBase-T R1000W |
|
|
|
Product Code: SY-SM-1029U-TN10RT
Special Order(Non-Refundable)
-----------------------------------------------------------
Product Description:
Supermicro Intel Server System
Due to the complexity of integration, this product is sold as completely assembled systems only (with minimum 2 CPU, 4 DIMM and 4 HDDs). Please contact our sales rep for special requirements.
Manufacturer Part Number:
Supermicro SYS-1029U-TN10RT, black color.
RoHS Compliant
Key Factor
• Virtualization
• Cloud Computing
• High End Enterprise Server
1. Dual socket P (LGA 3647) supports Intel® Xeon® Scalable Processors , Dual UPI up to 10.4GT/s
2. Up to 3TB ECC 3DS LRDIMM or RDIMM, up to DDR4-2666MHz; 24 DIMM slots
3. 2 PCI-E 3.0 x16 (FH, 10.5"L)
4. 2x 10GBase-T LAN ports
5. 10 Hot-swap 2.5" Drive Bays; 10 NVMe (4 hybrid ports - optional SAS3 via AOC);
2 internal M.2 (1 SATA3, 1 NVMe)
6. 8 Heavy duty fans w/ optimal fan speed control
7. 1000W Redundant Power Supplies Titanium Level (96%)
Specifications:
Product SKUs |
|
SYS-1029U-TN10RT |
- SuperServer 1029U-TN10RT (Black)
|
|
Motherboard |
|
Super X11DPU |
|
Processor/Cache |
|
CPU |
- Dual Socket P (LGA 3647) Cascade Lake/Skylake
- Intel® 2nd gen Xeon® Scalable Processors,
Dual UPI up to 10.4GT/s
- Support CPU TDP 70-205W with IVR
|
Cores |
- Up to 28 Cores with Intel® HT Technology
|
|
System Memory |
|
Memory Capacity |
- 24 DIMM slots
- Up to 3TB ECC 3DS LRDIMM, 3TB ECC RDIMM, DDR4 up to 2666MHz
|
Memory Type |
- 2666/2400/2133MHz ECC DDR4 SDRAM
|
|
On-Board Devices |
|
Chipset |
|
SATA |
- SATA3 (6Gbps); RAID 0, 1, 5, 10
|
Network Connectivity |
- 2 10GBase-T ports via AOC-URN6-i2XT
- Intel® X550 Dual Port 10GBase-T
- Virtual Machine Device Queues reduce I/O overhead
- Supports 10GBASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output
|
IPMI |
- Support for Intelligent Platform Management Interface v.2.0
- IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
|
Graphics |
|
|
Input / Output |
|
NVMe |
- 6 NVMe ports (NVMe from CPU 1)
- 4 NVMe Hybrid ports with optional SAS3 (NVMe from CPU 2)
|
LAN |
- 2 RJ45 10GBase-T ports
- 1 RJ45 Dedicated IPMI LAN port
|
USB |
- 5 USB 3.0 ports
(2 rear, 2 front, 1 Type A)
|
Video |
- 2 VGA ports (1 rear, 1 onboard)
|
Serial Port |
|
DOM |
- 2 SuperDOM (Disk on Module) ports
|
|
System BIOS |
|
BIOS Type |
|
|
Management |
|
Software |
- Intel® Node Manager
- Redfish API
- IPMI 2.0
- KVM with dedicated LAN
- NMI
- SSM, SPM, SUM
- SuperDoctor® 5
|
Power Configurations |
|
|
PC Health Monitoring |
|
CPU |
- Monitors for CPU Cores, Chipset Voltages, Memory.
- 4+1 Phase-switching voltage regulator
|
FAN |
- Fans with tachometer monitoring
- Status monitor for speed control
- Pulse Width Modulated (PWM) fan connectors
|
Temperature |
- Monitoring for CPU and chassis environment
- Thermal Control for 8x fan connectors
|
|
|
|
Chassis |
|
Form Factor |
|
Model |
|
|
Dimensions and Weight |
|
Height |
|
Width |
|
Depth |
|
Gross Weight |
|
Available Color |
|
|
Front Panel |
|
Buttons |
- Power On/Off button
- System UID button
|
LEDs |
- Power LED
- Hard drive activity LED
- Network activity LEDs
- UID LED
|
|
Expansion Slots |
|
PCI-Express |
- 2 PCI-E 3.0 x16 slots (Full-height, 10.5"L)
(Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.)
|
|
Drive Bays / Storage |
|
Hot-swap |
- 10 Hot-swap 2.5" drive bays
- 10 NVMe (4 hybrid ports for optional SAS3 via AOC)
|
M.2 |
- 1 M.2 NVMe (2242/2260/2280*/22110*)
- 1 M.2 SATA (2242/2260/2280*/22110*) via optional SATA cable
Not supported if installing both NVMe & SATA M.2
|
|
|
System Cooling |
|
Fans |
- 8 Heavy duty fans with optimal fan speed control
|
Air Shroud |
|
|
Power Supply |
1000W Redundant Power Supplies with PMBus |
Total Output Power |
|
Dimension
(W x H x L) |
|
Input |
- 100-127Vac / 9.8 - 7A / 50-60Hz
- 200-240Vac / 7 - 5A / 50-60Hz
|
+12V |
- Max: 66.7A / Min: 0A (100-127Vac)
- Max: 83A / Min: 0A (200-240Vac)
|
12Vsb |
|
Output Type |
- 25 Pairs Gold Finger Connector
|
Certification |
UL/cUL/CB/BSMI/CE/CCC
Titanium Level
[ Test Report ] |
|
Operating Environment |
|
RoHS |
|
Environmental Spec. |
- Operating Temperature:
10°C ~ 35°C (50°F ~ 95°F)
- Non-operating Temperature:
-40°C to 70°C (-40°F to 158°F)
- Operating Relative Humidity:
8% to 90% (non-condensing)
- Non-operating Relative Humidity:
5% to 95% (non-condensing)
|
|
|
|
|
|
|
|
|
|
Parts List - (Items Included) |
|
|
Part Number
|
Qty
|
Description
|
Motherboard / Chassis |
MBD-X11DPU
CSE-119UAC10-R1K02P-N10T |
1
1 |
Super X11DPU Motherboard
CSE-119UAC10-R1K02P-N10T |
Add-on Card / Module |
AOC-SLG3-2E4R-P |
1 |
NVMe AOC by 8,HF,RoHS/REACH |
Add-on Card / Module |
AOC-URN6-I2XT-P |
1 |
AOC-URN6-I2XT |
Backplane |
BPN-SAS3-116A-N10 |
1 |
10-port 1U SAS3 12Gbps Hybrid backplane, support up to 10x 2.5-inch NVMe storage devices, 4 of them are SAS3/SATA3 drives compatible. |
Cable 1 |
CBL-CDAT-0728 |
1 |
4 Pin to 4 Pin I2C cable, 65cm, 26AWG, 4 wires, pinout 1-1, for vpp header(jnvi2c1),RoHS/REACH |
Cable 2 |
CBL-PWEX-0780 |
1 |
PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),40/40CM,18AWG,RoHS |
Cable 3 |
CBL-PWEX-0781 |
1 |
PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),65/65CM,18AWG,RoHS |
Cable 4 |
CBL-SAST-0820 |
2 |
OCuLink v.91,INT,PCIe NVMe SSD, 85CM,34AWG |
Cable 5 |
CBL-SAST-0849 |
2 |
MiniSAS HD to OCuLink V.91,INT,PCIe NVMe SSD, 57CM,15D15F27D,34AWG,RoHS |
Cable 6 |
CBL-SAST-0964 |
1 |
Oculink v1.0 6x cable bundle 549/574/425/444/571/603mm 34AWG |
Parts |
MCP-130-81901-0N |
1 |
Oculink cable connection plastic holder for AOC-URN6-i2XT |
Air Shroud |
MCP-310-81910-0N |
1 |
Plastic air shroud for SC819U, 119U (X11 24DIMM, left side) |
Riser Card |
RSC-R1UW-2E16 |
1 |
RSC-R1UW-2E16-O-P |
Riser Card |
RSC-UMR-8 |
1 |
1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8,,HF,RoHS |
Heatsink / Retention |
SNK-P0067PS |
2 |
1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism |
Power Supply |
PWS-1K02A-1R |
2 |
1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH |
FAN 1 |
FAN-0101L4 |
8 |
40x56,4 Pin PWM,Primary for SC809,111, Sec.for SC816,819,808 |
Rear Window |
MCP-240-81909-0N |
1 |
Ultra I/O Rear Window for SC819U, 119U-T tool-less chassis(i2XT) |
|
|
|
|
Optional Parts List |
|
|
Part Number |
Qty |
Description |
Cable for 4x Hybrid NVMe/SATA Drive Bays |
CBL-SAST-0880 |
1 |
MINI SAS(RA-RS EXIT)-4 SATA,INT,55/55/55/55CM,55CM SB,30AWG for optional 4x SATA3 |
Storage Control Card and Cable for 4x Hybrid NVMe/SAS Drive Bays |
AOC-S3008L-L8e &
1 CBL-SAST-0948
AOC-S3008L-L8i &
1 CBL-SAST-0948
AOC-S3108L-H8iR &
1 CBL-SAST-0948 |
1
1
1 |
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 |
Cable for internal M.2 SATA |
CBL-SAST-0538 |
1 |
29cm 30AWG SATA S-RA cable |
Network Card(s) |
AOC-S40G-i2Q
AOC-SGP-i2
AOC-SGP-i4
AOC-STG-b4S
AOC-STGN-i2S
AOC-STGN-i1S
AOC-STG-i2T
AOC-STG-i2 |
-
-
-
-
-
-
-
- |
Standard LP 2-port 40GbE controller, based on Intel Fortville XL710
Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2
Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350
Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S
Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES
Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN
Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540
Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB |
CachVault(s) |
BTR-CV3108-1U1
BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05
BTR-TFM8G-LSICVM02 & MCP-240-00127-0N |
-
-
-
|
CacheVault for Broadcom 3108 with Supercap mounting in 1U 40x56 fan tray
CacheVault for Broadcom 3108; Supercap mounting bracket for PCI-E location
CacheVault for Broadcom 3108; Supercap mounting bracket for 2.5" HDD location |
Global Services & Support |
OS4HR3/2/1
OSNBD3/2/1 |
-
- |
3/2/1-year onsite 24x7x4 service
3/2/1-year onsite NBD service |
Software |
SFT-OOB-LIC |
1 |
OOB Management Package (per node license) |
Software |
SFT-DCMS-Single |
1 |
DataCenter Management Package (per node license) |
|
|
|
This product is not refundable due to manufacturer return policy. We only replace or repair defective product by RMA procedure.
This product is special order, which takes longer to process and cannot be returned.
|
|
|
|